Description: Niscomed 12 Channel ECG Machine - Flight 1200
Expected Delivery Date : 01 Sep, 2025
Country Of Origin : China
HSN Code : 90189019
Reference Code : Flight 201
Categories: ECG Machine , , ,
Rs. 160000
Rs. 43000.00 /- Only
You save Rs. 117000
Exclusive of 18% GST
Niscomed 12 Channel ECG Machine - Flight 1200
Expected Delivery Date: 01 Sep, 2025
Country Of Origin: China
HSN Code: 90189019
Reference Code: Flight 201
Categories: ECG Machine , , ,
Input Way: Floating Defibrillation Protection Lead: Standard 12 Leads Patient Leak Current: <10 µA Input Independence: ≥50 M Frequency response: 0.0 Hz~150 Hz(-3dB) Time constant: Time constant >3.2s CMRR: >60dB, >100dB (Adding filter) EMG Interference filter: 35 Hz_ -3d B Recording Way: Thermal Printing System Recording Paper Specification: 210 mm(W) x 20 mm(L) high-speed thermal paper Paper Speed: Auto record: 25mm/s, 50mm/s, error ± 5 % Rhythm record: 25mm/s, 50mm/s,error ± 5 % Manual record: 5mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s error ± 5 % Sensitivity Selections: 5, 10, 20, 40 mm/mV, error ± 5 % standard sensitivity is 10 mm/mV 0.2 mm/mv, Auto Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis Rhythm Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis Manual Record: Record Setup according to manual record format, manually changing leads
Input Way: Floating Defibrillation Protection Lead: Standard 12 Leads Patient Leak Current: <10 µA Input Independence: ≥50 M Frequency response: 0.0 Hz~150 Hz(-3dB) Time constant: Time constant >3.2s CMRR: >60dB, >100dB (Adding filter) EMG Interference filter: 35 Hz_ -3d B Recording Way: Thermal Printing System Recording Paper Specification: 210 mm(W) x 20 mm(L) high-speed thermal paper Paper Speed: Auto record: 25mm/s, 50mm/s, error ± 5 % Rhythm record: 25mm/s, 50mm/s,error ± 5 % Manual record: 5mm/s, 6.25 mm/s, 10 mm/s, 12.5 mm/s, 25 mm/s, 50mm/s error ± 5 % Sensitivity Selections: 5, 10, 20, 40 mm/mV, error ± 5 % standard sensitivity is 10 mm/mV 0.2 mm/mv, Auto Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis Rhythm Record: Record Setup according to auto record format & mode, automatically change leads measuring & analysis Manual Record: Record Setup according to manual record format, manually changing leads
Average
13 Review
Excellent
Very Good
Average
Poor
Terrible
Showing 1 - 6 of 13 reviews
415 Reena complex Vidyavihar station West opposite neelkanth business park mumbai 400086
info@quali55care.com
+91 9643503583
Mon-Sat : 9:10 to 7:30
$30.00
$60.00
$40.00
-25%
$65.00
$35.00
$15.00
Lost password? Recover password
Featured
Best selling
Alphabetically, A-Z
Alphabetically, Z-A
Price, low to high
Price, high to low
Date, old to new
Date, new to old
Accessories
Men
Women
Shoes
T-Shirt
Dress
Jackets
Boots
Jewellery
Tops
Wallet
$75.00$45.00
$60.00$45.00
$22.00
Free shipping for all US order
We support 24 hours a day
You have 30 days to return